Command |
Description |
COM analog |
||
---|---|---|---|---|
Averaging ON/OFF |
+ |
|||
Restart averaging |
+ |
|||
Averaging factor |
+ |
|||
IF bandwidth |
+ |
|||
IF bandwidth |
+ |
|||
Clears the table of calibration factors |
+ |
|||
Clears data of calibration standards |
+ |
|||
Information string of calibration |
+ |
|||
S-parameter error correction state |
+ |
|||
Calibration trigger source |
+ |
|||
Information about trace (calibration type, number of ports) |
+ |
|||
Calibration coefficient data |
+ |
|||
Selects one-path two-port method |
+ |
|||
Selects Response Open method |
+ |
|||
Selects Response Short method |
+ |
|||
Selects full one-port method |
+ |
|||
Selects full two-port method |
+ |
|||
Selects full free-port method |
+ |
|||
Selects Full four-port method |
+ |
|||
Selects Response Thru method |
+ |
|||
Enables calibration coefficients |
+ |
|||
Approximate delay of the adapter |
- |
|||
Approximate length of the adapter |
- |
|||
Delay units |
- |
|||
Adapter media |
- |
|||
Permittivity of the adapter media |
- |
|||
Cutoff frequency of the waveguide adapter |
- |
|||
Adapter Removal/Insertion ON/OFF |
- |
|||
Calibration kit selection |
+ |
|||
Calibration kit description string |
- |
|||
Calibration kit label |
+ |
|||
Remove or restore a calibration kit |
+ |
|||
Insert the standard into a calibration kit |
- |
|||
Delete the standard from a calibration kit |
- |
|||
"Load" class |
+ |
|||
"Open" class |
+ |
|||
Assignment of subclass |
+ |
|||
"Short" class |
+ |
|||
"Thru" class |
+ |
|||
"TRL Line" class |
+ |
|||
"TRL Thru" class |
+ |
|||
"TRL Reflect" class |
+ |
|||
Arbitrary impedance (Load) |
+ |
|||
Capacitance C0 (Open) |
+ |
|||
Capacitance C1 (Open) |
+ |
|||
Capacitance C2 (Open) |
+ |
|||
Capacitance C3 (Open) |
+ |
|||
Number of standards in the calibration kit |
- |
|||
S-parameters of the data-based calibration standard |
- |
|||
Offset delay |
+ |
|||
Max frequency |
+ |
|||
Min frequency |
+ |
|||
Inductance L0 (Short) |
+ |
|||
Inductance L1 (Short) |
+ |
|||
Inductance L2 (Short) |
+ |
|||
Inductance L3 (Short) |
+ |
|||
Standard label |
+ |
|||
Offset loss |
+ |
|||
Standard type |
+ |
|||
Offset Z0 |
+ |
|||
Measurement array of Isolation |
+ |
|||
Measurement array of Load |
+ |
|||
Measurement array of Open |
+ |
|||
Measurement array of Short |
+ |
|||
Reflection measurement array of Thru |
+ |
|||
Transmission measurement array of Thru |
+ |
|||
Confidence check of calibration coefficients |
+ |
|||
Procedure of one path two-port calibration |
+ |
|||
Information about connected module |
+ |
|||
Auto-Orientation procedure |
+ |
|||
Auto-Orientation ON/OFF |
+ |
|||
Manual module orientation |
+ |
|||
Procedure of one-port calibration |
+ |
|||
Procedure of full two-port calibration |
+ |
|||
Procedure of full three-port calibration |
+ |
|||
Procedure of full four-port calibration |
+ |
|||
Thermo compensation ON/OFF |
- |
|||
Characterization number |
+ |
|||
Unknown Thru feature ON/OFF |
+ |
|||
Executes the full three-(four-)port calibration used two-port ACM |
- |
|||
Ports selection for the three-port calibration used two-port ACM |
- |
|||
Ports selection for the four-port calibration used two-port ACM |
- |
|||
Measurement of Thru during the full three-(four-)port calibration used two-port ACM |
- |
|||
Completes the full three-(four-)port calibration used two-port ACM |
- |
|||
Isolation |
+ |
|||
Load |
+ |
|||
Open |
+ |
|||
Short |
+ |
|||
Thru |
+ |
|||
TRL Line |
+ |
|||
TRL Thru |
+ |
|||
TRL Reflect |
+ |
|||
Subclass number |
+ |
|||
One path two-port |
+ |
|||
Response Open |
+ |
|||
Response Short |
+ |
|||
Full one-port (SOL) |
+ |
|||
Full two-port (SOLT) |
+ |
|||
Full three-port (SOLT) |
+ |
|||
Full four-port (SOLT) |
+ |
|||
Response Thru |
+ |
|||
Multi-line TRL option ON/OFF |
- |
|||
Two-port TRL |
+ |
|||
Three-port TRL |
+ |
|||
Four-port TRL |
+ |
|||
Calibration method query. |
+ |
|||
Calibration completion |
+ |
|||
Completion of simplified three/four-port calibration |
+ |
|||
Approximate delay of the Thru |
- |
|||
Approximate length of the Thru |
- |
|||
Delay Units |
- |
|||
Thru Media |
- |
|||
Permittivity of the Thru media |
- |
|||
Cutoff frequency of the waveguide Thru |
- |
|||
Completion of the full two-port calibration |
- |
|||
Ports selection for the three-port calibration |
- |
|||
Measurement of Thru during the full three-port calibration |
- |
|||
Completion of the full three-port calibration |
- |
|||
Measurement of Thru during the full four-port calibration |
- |
|||
Completion of the full four-port calibration |
- |
|||
Port extension ON/OFF |
+ |
|||
Values of "Frequency1" and "Frequency2" |
+ |
|||
Loss compensation ON/OFF |
+ |
|||
Value "Loss at DC" |
+ |
|||
Values of "Loss 1" and "Loss 2" |
+ |
|||
Extension Port n |
+ |
|||
Frequency range configuration |
- |
|||
"Loss at DC" value ON/OFF |
- |
|||
"Loss1" and "Loss2" values ON/OFF |
- |
|||
Measurement of Short or Open |
- |
|||
Auto port extension for the specified port ON/OFF |
- |
|||
Restart averaging between Short and Open |
- |
|||
Start frequency of user span |
- |
|||
Stop frequency of user span |
- |
|||
System Z0 |
+ |
|||
Auto-select Z0 ON/OFF |
- |
|||
System Z0 for the specified port |
- |
|||
Clears calibration coefficient table |
+ |
|||
Clears calibration data |
+ |
|||
Calibration direction |
- |
|||
Measure all standards using ACM |
- |
|||
Measure the Load standard |
+ |
|||
Calibration port |
+ |
|||
Measure the Open standard |
+ |
|||
Measure power |
+ |
|||
Measure the Short standard |
+ |
|||
Measure the Thru standard |
+ |
|||
Completes calibration |
+ |
|||
Receiver correction ON/OFF |
+ |
|||
Calibration procedure for both receivers |
+ |
|||
Reference receiver calibration procedure |
+ |
|||
Test receiver calibration procedure |
+ |
|||
Power offset |
+ |
|||
Frequency at which cable loss specified |
+ |
|||
Cable loss |
+ |
|||
Cable velocity factor |
+ |
|||
Cable correction ON/OFF |
+ |
|||
Complete the calibration using ACM |
- |
|||
Port number for calibration mixer with LPF filter |
- |
|||
IF frequency (RF+LO, RF-LO, LO-RF) |
- |
|||
LO frequency |
- |
|||
Measure the Load standard |
- |
|||
Measure the Open standard |
- |
|||
Measure the Short standard |
- |
|||
Setup option (de-embedding calibration mixer + filter at completion of calibration) ON/OFF |
- |
|||
Complete the calibration, calculate S-parameters, write the touchstone file |
- |
|||
Corrected S-parameter data or corrected receiver data |
+ |
|||
Raw S-parameter data or raw receiver data |
+ |
|||
Stimulus data |
+ |
|||
Fixed frequency for a power sweep |
+ |
|||
Center frequency |
+ |
|||
Span frequency |
+ |
|||
Start frequency |
+ |
|||
Stop frequency |
+ |
|||
Segment sweep table |
+ |
|||
Sweep Time |
- |
|||
Number of points |
+ |
|||
Point delay |
+ |
|||
Reverse sweep ON/OFF |
+ |
|||
Sweep type |
+ |
|||
Frequency offset adjust ON/OFF |
- |
|||
Adjust period |
- |
|||
Executes adjustment once |
- |
|||
Adjustment path |
- |
|||
Adjusted Ports |
- |
|||
Adjust Value |
- |
|||
Frequency offset ON/OFF |
+ |
|||
Port offset data |
+ |
|||
Port offset settings |
Divisor |
+ |
||
Multiplier |
+ |
|||
Offset |
+ |
|||
Start |
+ |
|||
Stop |
+ |
|||
Receiver offset data |
+ |
|||
Receiver offset settings |
Divisor |
+ |
||
Multiplier |
+ |
|||
Offset |
+ |
|||
Start |
+ |
|||
Stop |
+ |
|||
Source offset data |
+ |
|||
Source offset settings |
Divisor |
+ |
||
Multiplier |
+ |
|||
Offset |
+ |
|||
Start |
+ |
|||
Stop |
+ |
|||
Offset type |
+ |
|||
Reference source |
+ |
|||
DC voltage range |
- |