 Network Analyzers using RVNA and RNVNA software

Command

Description

COM analog

SENS:AVER

Averaging

Averaging ON/OFF

+

SENS:AVER:CLE

Restart averaging

+

SENS:AVER:COUN

Averaging factor

+

SENS:BAND

IFBW

IF bandwidth

+

SENS:BWID

IF bandwidth

+

SENS:CORR:CLE

Misc Calibration Commands

Clears the table of calibration factors

+

SENS:CORR:COLL:CLE

Clears data of calibration standards

+

SENS:CORR:STAT

S-parameter error correction state

+

SENS:CORR:TYPE?

Information about trace (calibration type, number of ports)

+

SENS:CORR:COEF

Read/Write Calibration Coefficients

Calibration coefficient data

+

SENS:CORR:COEF:METH:OPEN

Selects Response Open method

+

SENS:CORR:COEF:METH:SHOR

Selects Response Short method

+

SENS:CORR:COEF:METH:SOLT1

Selects full one-port method

+

SENS:CORR:COEF:METH:THRU

Selects Response Thru method

-

SENS:CORR:COEF:SAVE

Enables calibration coefficients

+

SENS:CORR:COLL:CKIT

Calibration Kit Management

Calibration kit selection

+

SENS:CORR:COLL:CKIT:LAB

Calibration kit label

+

SENS:CORR:COLL:CKIT:RES

Remove or restore a calibration kit

+

SENS:CORR:COLL:CKIT:STAN:C0

Calibration Standard Definition

Capacitance C0 (Open)

+

SENS:CORR:COLL:CKIT:STAN:C1

Capacitance C1 (Open)

+

SENS:CORR:COLL:CKIT:STAN:C2

Capacitance C2 (Open)

+

SENS:CORR:COLL:CKIT:STAN:C3

Capacitance C3 (Open)

+

SENS:CORR:COLL:CKIT:STAN:DEL

Offset delay

+

SENS:CORR:COLL:CKIT:STAN:FMAX

Max frequency

+

SENS:CORR:COLL:CKIT:STAN:FMIN

Min frequency

+

SENS:CORR:COLL:CKIT:STAN:HWR

Waveguide height to width ratio value

-

SENS:CORR:COLL:CKIT:STAN:L0

Inductance L0 (Short)

+

SENS:CORR:COLL:CKIT:STAN:L1

Inductance L1 (Short)

+

SENS:CORR:COLL:CKIT:STAN:L2

Inductance L2 (Short)

+

SENS:CORR:COLL:CKIT:STAN:L3

Inductance L3 (Short)

+

SENS:CORR:COLL:CKIT:STAN:LAB

Standard label

+

SENS:CORR:COLL:CKIT:STAN:LOSS

Offset loss

+

SENS:CORR:COLL:CKIT:STAN:MEDI

Media

-

SENS:CORR:COLL:CKIT:STAN:TYPE

Standard type

+

SENS:CORR:COLL:CKIT:STAN:Z0

Offset Z0

+

SENS:CORR:COLL:DATA:LOAD

Read/Write Measurement of Calibration Standards

Measurement array of Load (1-port VNA only)

+

SENS:CORR:COLL:DATA:OPEN

Measurement array of Open (1-port VNA only)

+

SENS:CORR:COLL:DATA:SHOR

Measurement array of Short (1-port VNA only)

+

SENS:CORR:COLL:ECAL:INF?

Automatic Calibration Module

Information about connected module

+

SENS:CORR:COLL:ECAL:ORI:EXEC

Auto-Orientation procedure

+

SENS:CORR:COLL:ECAL:ORI:STAT

Auto-Orientation ON/OFF

+

SENS:CORR:COLL:ECAL:CHECK:EXEC

Confidence check

+

SENS:CORR:COLL:ECAL:PATH

Manual module orientation

+

SENS:CORR:COLL:ECAL:SOLT1

Procedure of one-port calibration

+

SENS:CORR:COLL:ECAL:SOLT2

Procedure of full two-port calibration

+

SENS:CORR:COLL:ECAL:UCH

Characterization number

+

SENS:CORR:COLL:LOAD

Measurement of Calibration Standards

Load

+

SENS:CORR:COLL:OPEN

Open

+

SENS:CORR:COLL:SHOR

Short

+

SENS:CORR:COLL:THRU

Thru

+

SENS:CORR:COLL:METH:ERES

Calibration Method

One path two-port

+

SENS:CORR:COLL:METH:OPEN

Response Open

+

SENS:CORR:COLL:METH:SHOR

Response Short

+

SENS:CORR:COLL:METH:SOLT1

Full one-port (SOL)

+

SENS:CORR:COLL:METH:SOLT2

SENS:CORR:COLL:METH:THRU

Full two-port (SOLT)

+

Response Thru

+

SENS:CORR:COLL:METH:TYPE?

Calibration method query.

+

SENS:CORR:COLL:SAVE

Calibration Completion

Calibration completion

+

SENS:CORR:EXT

Port Extension

Port extension ON/OFF

+

SENS:CORR:EXT:PORT:FREQ

Values of "Frequency1" and "Frequency2"

+

SENS:CORR:EXT:PORT:INCL

Loss compensation ON/OFF

+

SENS:CORR:EXT:PORT:LDC

Value "Loss at DC"

+

SENS:CORR:EXT:PORT:LOSS

Loss compensation ON/OFF

+

SENS:CORR:EXT:PORT:TIME

Extension Port n

+

SENS:CORR:EXT:AUTO:CONF

Auto Port Extension

Frequency range configuration

+

SENS:CORR:EXT:AUTO:DCOF

"Loss at DC" value ON/OFF

+

SENS:CORR:EXT:AUTO:LOSS

"Loss1" and "Loss2" values ON/OFF

+

SENS:CORR:EXT:AUTO:MEAS

Measurement of Short or Open

+

SENS:CORR:EXT:AUTO:SAVE

Set port extension parameters

+

SENS:CORR:EXT:AUTO:RES

Restart averaging between Short and Open

+

SENS:CORR:EXT:AUTO:STAR

Start frequency of user span

+

SENS:CORR:EXT:AUTO:STOP

Stop frequency of user span

+

SENS:CORR:IMP

System Impedance Setting

System Z0

+

SENS:CORR:TRAN:TIME:FREQ

Cable Correction

Frequency at which cable loss specified

+

SENS:CORR:TRAN:TIME:LOSS

Cable loss

+

SENS:CORR:TRAN:TIME:RVEL

Cable velocity factor

+

SENS:CORR:TRAN:TIME:STAT

Cable correction ON/OFF

+

SENS:CABL:SEL

Selection of the cable in the cable list

-

SENS:CABL:COUN

Number of cables in the cable list

-

SENS:FREQ:DATA?

Data Transfer

Stimulus data

+

SENS:FREQ:CENT

Stimulus Settings

Center frequency

+

SENS:FREQ:SPAN

Span frequency

+

SENS:FREQ:STAR

Start power

+

SENS:FREQ:STOP

Stop power

+

SENS:SEGM:DATA

Segment sweep table

+

SENS:SWE:POIN

Number of points

+

SENS:SWE:POIN:TIME

Point delay

+

SENS:SWE:TYPE

Sweep type

+

SENS:ROSC:SOUR

Analyzer Parameters

Reference source

+