Display | Print | Files | Analysis | Marker | Average | Calibration
Stimulus | Trigger | Scale | Channels | Trace | System | Devices* | Remote Only
Calibration | Cal Kit: Edit Cal Kit | Meas STDs | Port Extension: Auto Port Ext | AutoCal | Remote Only: Misc Commands | R/W Meas of Cal STDs | R/W Cal Coefficients
note |
This icon indicates a read only command. This icon indicates a write only command. This icon indicates command(s) without equivalent softkeys. Comments are in italics. |
Calibration |
|
---|---|
Correction (ON/OFF) |
|
System Z0 |
Edit Cal Kit (Calibration kit) |
|
---|---|
Label |
|
Standard Type |
|
Standard Label |
|
C0 [e-15 F] |
|
C1 [e-27 F/Hz] |
|
C2 [e-36 F/Hz^2] |
|
C3 [e-45 F/Hz^3] |
|
L0 [e-12 H] |
|
L1 [e-24 H/Hz] |
|
L2 [e-33 H/Hz^2] |
|
L3 [e-42 H/Hz^3] |
|
Offset Delay [ps] |
|
Offset Z0 [Ohm] |
|
Offset Loss [GOhm/s] |
|
F min, [MHz] |
|
F max, [MHz] |
|
Media |
|
H/W (waveguide height to width ratio) |
|
Save To File |
|
Restore Cal Kit |
|
Load From File |
Measurement of Calibration Standards (Calibration) |
||
---|---|---|
Open |
||
Short |
||
Load |
||
Thru |
||
Cancel |
||
Apply |
||
|
Response calibration (Open) |
|
|
Response calibration (Short) |
|
Calibration method: |
Response calibration (Thru) |
|
Full 1-port calibration |
||
|
One path 2-port calibration |
|
|
Full 2-port calibration with scalar Thru |
|
Calibration method query |
Port Extension |
|
---|---|
Port Extension (ON/OFF) |
|
Extension Value |
|
Loss n (ON/OFF) |
|
Loss n Value |
|
Frequency n |
|
Loss at DC |
Auto Port Extension (Port Extension) |
|
---|---|
Method (Current Span | User Span | Active Marker) |
|
Frequency 1 |
|
Frequency 2 |
|
Include Loss (ON/OFF) |
|
Adjust Mismatch (ON/OFF) |
|
Open, Short |
|
Cancel |
|
Apply |
Autocalibration |
||
---|---|---|
Characterization |
||
Orientation (AUTO) |
||
Orientation (Port А | Port В) |
||
Perform Auto-Orientation |
||
Characterization Info |
||
Confidence Check |
||
Calibrate |
Full one-port calibration |
|
One path 2-port calibration in both directions |
||
THRU state |
||
Impedance state of the specified port (Open | Short | Load) |
||
Temperature of the AutoCal module |
Misc Calibration Commands |
|
---|---|
Clears the calibration coefficient table |
|
Сalibration information |
Read/Write Measurement Data of Calibration Standards |
|
---|---|
Load |
|
Open |
|
Short |
Read/Write Calibration Coefficients |
||
---|---|---|
Selects the type of calibration before enabling calibration coefficients |
Response calibration (Open) |
|
Response calibration (Short) |
||
Response calibration (Thru) |
||
Full one-port calibration |
||
Сalibration coefficient data array |
||
Enables the written calibration coefficients depending on the selected calibration type. |