 Network Analyzers using S2VNA software


note

This icon Read only indicates a read only command. This icon Write only indicates a write only command.

This icon Remote only indicates command(s) without equivalent softkeys.

Comments are in italics.


Calibration

Correction (ON/OFF)

SENS:CORR:STAT

Cal Trig Source (Internal | System)

SENS:CORR:TRIG:FREE

 

Calibrate

 

Response (Open) Write only

SENS:CORR:COLL:METH:OPEN

 

Response (Short) Write only

SENS:CORR:COLL:METH:SHOR

 

Response (Thru) Write only

SENS:CORR:COLL:METH:THRU

Method

Full 1-Port Cal Write only

SENS:CORR:COLL:METH:SOLT1

 

One Path 2–Port Cal Write only

SENS:CORR:COLL:METH:ERES

 

2-Port (SOLT) Cal Write only

SENS:CORR:COLL:METH:SOLT2

 

2-Port TRL Cal Write only

SENS:CORR:COLL:METH:TRL2

Multiline TRL (ON/OFF)

SENS:CORR:COLL:METH:TRL:MULT

Apply Write only

SENS:CORR:COLL:SAVE

Cancel Write only

SENS:CORR:COLL:CLE

Calibration method query Remote only Read only

SENS:CORR:COLL:METH:TYPE?

 

Measurement of Calibration Standards (Calibrate)

For calibrations:

Response

Full 1–Port Cal

One Path 2–Port Cal

2–Port SOLT Cal

Open Write only

SENS:CORR:COLL:OPEN

Short Write only

SENS:CORR:COLL:SHOR

Load Write only

SENS:CORR:COLL:LOAD

Thru Write only

SENS:CORR:COLL:THRU

Isolation (Optional) Write only

SENS:CORR:COLL:ISOL

In calibration:

2–Port TRL Cal

1-2 Thru/Line Write only

SENS:CORR:COLL:TRLT

Port n Reflect Write only

SENS:CORR:COLL:TRLR

1-2 Line/Match Write only

SENS:CORR:COLL:TRLL

Subclass number Remote only

SENS:CORR:COLL:SUBC

 

Adapter Removal/Insertion (Calibrate)

Select Port Write only

SENS:CORR:COLL:METH:ADAP:REM

Adapter Delay

SENS:CORR:COLL:ADAP:DEL

SENS:CORR:COLL:ADAP:LENG

Adapter Media (Coaxial | Waveguide)

SENS:CORR:COLL:ADAP:MED

Delay Unit (Seconds | Meters)

SENS:CORR:COLL:ADAP:UNIT

Permittivity

SENS:CORR:COLL:ADAP:PERM

Cutoff Frequency

SENS:CORR:COLL:ADAP:WAV:CUT

 

Unknown Thru Addition (Calibrate)

Thru Delay

SENS:CORR:COLL:THRU:ADD:DEL

SENS:CORR:COLL:THRU:ADD:LENG

Thru Media (Coax | Waveguide)

SENS:CORR:COLL:THRU:ADD:MED

Delay Unit (Seconds | Meters)

SENS:CORR:COLL:THRU:ADD:UNIT

Permittivity

SENS:CORR:COLL:THRU:ADD:PERM

Cutoff Frequency

SENS:CORR:COLL:THRU:ADD:WAV:CUT

Complete 2-Port Calibration

Write only

SENS:CORR:COLL:THRU:ADD:FULL2:COMP

 

 

Define STDs (Cal Kit)

Add STD Write only

SENS:CORR:COLL:CKIT:STAN:INS

Delete STD Write only

SENS:CORR:COLL:CKIT:STAN:REM

Define STD Data

SENS:CORR:COLL:CKIT:STAN:DATA

Define STDs Read only

(The count of standards in the selected calibration kit is equal to the number of rows in the Standards table)

SENS:CORR:COLL:CKIT:STAN:COUN?

*The following are the column labels in the Table of Standards:

 

Standard_Type

SENS:CORR:COLL:CKIT:STAN:TYPE

Standard_Label

SENS:CORR:COLL:CKIT:STAN:LAB

Frequency_Fmin

SENS:CORR:COLL:CKIT:STAN:FMIN

Frequency_Fmax

SENS:CORR:COLL:CKIT:STAN:FMAX

Offset_Delay

SENS:CORR:COLL:CKIT:STAN:DEL

Offset_Z0

SENS:CORR:COLL:CKIT:STAN:Z0

Offset_Loss

SENS:CORR:COLL:CKIT:STAN:LOSS

Terminal Impedance (Load)

SENS:CORR:COLL:CKIT:STAN:ARB

C0 10–15 F (Open)

SENS:CORR:COLL:CKIT:STAN:C0

C1 10–27 F/Hz (Open)

SENS:CORR:COLL:CKIT:STAN:C1

C2 10–36 F/Hz2 (Open)

SENS:CORR:COLL:CKIT:STAN:C2

C3 10–45 F/Hz3 (Open)

SENS:CORR:COLL:CKIT:STAN:C3

L0 10–12 H (Short)

SENS:CORR:COLL:CKIT:STAN:L0

L1 10–24 H/Hz (Short)

SENS:CORR:COLL:CKIT:STAN:L1

L2 10–33 H/Hz2 (Short)

SENS:CORR:COLL:CKIT:STAN:L2

L3 10–42 H/Hz3 (Short)

SENS:CORR:COLL:CKIT:STAN:L3

 

Specify CLS (Cal Kit)

*The following are the column labels in the Table of calibration standard classes:

 

Subclass n (Select column)

SENS:CORR:COLL:CKIT:ORD:SEL

Load Port x (Fill row)

SENS:CORR:COLL:CKIT:ORD:LOAD

Open Port x (Fill row)

SENS:CORR:COLL:CKIT:ORD:OPEN

Short Port x (Fill row)

SENS:CORR:COLL:CKIT:ORD:SHOR

Thru Port x-y (Fill row)

SENS:CORR:COLL:CKIT:ORD:THRU

TRL Line Port x-y (Fill row)

SENS:CORR:COLL:CKIT:ORD:TRLL

TRL Thru Port x-y (Fill row)

SENS:CORR:COLL:CKIT:ORD:TRLT

TRL Reflect Port x-y (Fill row)

SENS:CORR:COLL:CKIT:ORD:TRLR

 

Power Calibration

Power Sensor Zero Correction Write only

SYST:COMM:PSEN:ZERO

Take Cal Sweep Write only

SOUR:POW:PORT:CORR:COLL

Correction (ON/OFF)

SOUR:POW:PORT:CORR

Loss Compensation (ON/OFF)

SOUR:POW:PORT:CORR:COLL:TABL:LOSS

Loss Compen (data)

SOUR:POW:PORT:CORR:COLL:TABL:LOSS:DATA

Export Loss Table Write only

MMEM:STOR:PLOS

Import Loss Table Write only

MMEM:LOAD:PLOS

Status of power correction (Interpolation/extrapolation) Remote only Read only

SOUR:POW:PORT:CORR:INT?

Power correction data Remote only

SOUR:POW:PORT:CORR:DATA

 

Receiver Calibration

Correction (ON/OFF)

SENS:CORR:REC

Calibrate Test Receiver Write only

SENS:CORR:REC:COLL:TCH:ACQ

Calibrate Reference Receiver Write only

SENS:CORR:REC:COLL:RCH:ACQ

Calibrate Both Write only

SENS:CORR:REC:COLL:ACQ

Power Offset

SENS:CORR:REC:OFFS:AMPL

 

Scalar (Mixer Calibration)

Select ports Write only

SENS:CORR:OFFS:COLL:METH:SMIX2

Direction (Forward | Revers | Both)

SENS:CORR:OFFS:COLL:DIR

Port n Open Write only

SENS:CORR:OFFS:COLL:OPEN

Port n Short Write only

SENS:CORR:OFFS:COLL:SHOR

Port n Load Write only

SENS:CORR:OFFS:COLL:LOAD

Port n-m Thru Write only

SENS:CORR:OFFS:COLL:THRU

Power Write only

SENS:CORR:OFFS:COLL:PMET

Measure STDs Using ACM Write only

SENS:CORR:OFFS:COLL:ECAL

Apply Write only

SENS:CORR:OFFS:COLL:SAVE

Cancel Write only

SENS:CORR:OFFS:COLL:CLE

Clear calibration coefficients Remote only Write only

SENS:CORR:OFFS:CLE

 

Vector (Mixer Calibration)

Select Port

SENS:CORR:VMC:COLL:PORT

LO Frequency

SENS:CORR:VMC:COLL:LO:FREQ

IF Frequency (RF+LO | RF-LO | LO-RF)

SENS:CORR:VMC:COLL:IF:SEL

Open Write only

SENS:CORR:VMC:COLL:OPEN

Short Write only

SENS:CORR:VMC:COLL:SHOR

Load Write only

SENS:CORR:VMC:COLL:LOAD

Save To Touchstone File Write only

SENS:CORR:VMC:COLL:SAVE

Execute Using ACM Write only

SENS:CORR:VMC:COLL:ECAL:SAVE

Setup Option (ON/OFF)

SENS:CORR:VMC:COLL:OPT

 

Port Extension

Extension (ON/OFF)

SENS:CORR:EXT

Extension Port n

SENS:CORR:EXT:PORT:TIME

Loss1 (ON/OFF), Loss2 (ON/OFF)

SENS:CORR:EXT:PORT:INCL

Freq1, Freq2

SENS:CORR:EXT:PORT:FREQ

Loss1, Loss2

SENS:CORR:EXT:PORT:LOSS

Loss at DC

SENS:CORR:EXT:PORT:LDC

 

Auto (Port Extension)

Select Port(s)

SENS:CORR:EXT:AUTO:PORT

Method (Current span | Active Marker | User Span)

SENS:CORR:EXT:AUTO:CONF

Include Loss (ON/OFF)

SENS:CORR:EXT:AUTO:LOSS

Adjust Mismatch (ON/OFF)

SENS:CORR:EXT:AUTO:DCOF

User Span Start

SENS:CORR:EXT:AUTO:STAR

User Span Stop

SENS:CORR:EXT:AUTO:STOP

Auto Port Extension

SENS:CORR:EXT:AUTO:RES

Measure Short, Measure Open

SENS:CORR:EXT:AUTO:MEAS

 

System Z0

System Z0

SENS:CORR:IMP

Port n Z0

SENS:CORR:PORT:IMP

Auto Select Z0 (ON/OFF)

SENS:CORR:IMP:SEL:AUTO

 

AutoCal Module

1-Port AutoCal > Port n Write only

SENS:CORR:COLL:ECAL:SOLT1

One Path 2–Port AutoCal > Port n->m Write only

SENS:CORR:COLL:ECAL:ERES

2-Port AutoCal Write only

SENS:CORR:COLL:ECAL:SOLT2

Characterization

SENS:CORR:COLL:ECAL:UCH

Auto-Orientation (ON/OFF)

SENS:CORR:COLL:ECAL:ORI:STAT

Execute Auto-Orientation

SENS:CORR:COLL:ECAL:ORI:EXEC

Port n (Orientation)

SENS:CORR:COLL:ECAL:PATH

Unkn Thru (ON/OFF)

SENS:CORR:COLL:ECAL:UTHR:STAT

Thermo Compensation (ON/OFF)

SENS:CORR:COLL:ECAL:THER:COMP

Characterization Info… Read only

SENS:CORR:COLL:ECAL:INF?

Confidence Check Write only

SENS:CORR:COLL:ECAL:CCH

 

AutoCal Remote only

Set "CHECK" Write only

SYST:COMM:ECAL:CHEC

Set "THRU" Write only

SYST:COMM:ECAL:THRU

Characterization data Read only

SYST:COMM:ECAL:DATA?

Characterization frequency array Read only

SYST:COMM:ECAL:FREQ:DATA?

Number of characterization points Read only

SYST:COMM:ECAL:POIN?

Set port Impedance (OPEN|SHORT|LOAD)

SYST:COMM:ECAL:IMP

Readiness status Read only

SYST:COMM:ECAL:READ?

Temperature of module Read only

SYST:COMM:ECAL:TEMP:SENS?

 

Misc Calibration Commands Remote only

Clears the table of calibration coefficients Write only

SENS:CORR:CLE

Calibration Information Read only

SENS:CORR:INF?

SENS:CORR:TYPE?

Interpolation/extrapolation status of error correction Read only

CALC:CORR:STAT?

 

Read/Write Measurement Data of Calibration Standards Remote only

Thru Reflection

SENS:CORR:COLL:DATA:THRU:MATC

Thru Transmission

SENS:CORR:COLL:DATA:THRU:TRAN

Load

SENS:CORR:COLL:DATA:LOAD

Open

SENS:CORR:COLL:DATA:OPEN

Short

SENS:CORR:COLL:DATA:SHOR

Isolation

SENS:CORR:COLL:DATA:ISOL

 

Read/Write Calibration Coefficients Remote only

Sets method before activation

Response Open Write only

SENS:CORR:COEF:METH:OPEN

Response Short Write only

SENS:CORR:COEF:METH:SHOR

Response Thru Write only

SENS:CORR:COEF:METH:THRU

One-path two-port Write only

SENS:CORR:COEF:METH:ERES

Full one-port Write only

SENS:CORR:COEF:METH:SOLT1

Full two-port Write only

SENS:CORR:COEF:METH:SOLT2

Calibration coefficient data read/write

SENS:CORR:COEF

Activates written calibration coefficients Write only

SENS:CORR:COEF:SAVE

Rev.:  24.1