Stimulus | Response | Scale | Calibration | Channel | Trace | Markers | Analysis | Display | System | Remote Only
Calibration | Calibrate: Meas STDs | Cal Kit: Edit Cal Kit | AutoCal Module | Power Calibration | Port Extension: Auto Port Extension | System Z0 | Remote Only: Misc Commands | R/W Meas of Cal STDs | R/W Cal Coefficients
note |
This icon indicates a read only command. This icon indicates a write only command. This icon indicates command(s) without equivalent softkeys. Comments are in italics. |
Calibrate |
||
---|---|---|
|
Response (Open) |
|
|
Response (Short) |
|
Method |
Response (Thru) |
|
|
Full 1-Port Cal |
|
|
One Path 2-Port Cal |
|
Apply |
||
Cancel |
||
Calibration method query |
Measurement of Calibration Standards (Calibrate) |
||
---|---|---|
For calibrations: •Response •Full 1–Port Cal •One Path 2–Port Cal |
Open |
|
Short |
||
Load |
||
Thru |
Cal Kit |
|
---|---|
Select |
|
Restore Cal Kit |
|
Save To File |
|
Load From File |
Edit Cal Kit (Cal Kit) |
||
---|---|---|
Label |
||
STD Type |
||
Capacitance (Open) |
C0 10–15 F |
|
C1 10–27 F/Hz |
||
C2 10–36 F/Hz2 |
||
C3 10–45 F/Hz3 |
||
Inductance (Short) |
L0 10–12 H |
|
L1 10–24 H/Hz |
||
L2 10–33 H/Hz2 |
||
L3 10–42 H/Hz3 |
||
Offset Delay |
||
Offset Z0 |
||
Offset Loss |
||
Freq min |
||
Freq max |
||
Standard Label |
||
Reading Load number |
||
Reading Open number |
||
Reading Short number |
||
Reading Thru number |
||
Waveguide height to width ratio |
||
Media type |
AutoCal Module |
|
---|---|
Full 1-Port Calibration |
|
One Path 2–Port Calibration |
|
Characterization |
|
Auto (ON/OFF) (Orientation) |
|
Port n -> Port m (Orientation) |
|
Perform Auto-Orientation |
|
Characterization Info |
|
Confidence Check |
|
Set "THRU" module state |
|
Set port Impedance (OPEN|SHORT|LOAD) |
|
Module temperature |
Power Calibration |
|
---|---|
Correction (ON/OFF) |
|
Read power correction data |
Port Extension |
||
---|---|---|
Extension (ON/OFF) |
||
Extension Port n |
||
Loss |
Loss n (ON/OFF) |
|
Loss n |
||
Freq n |
||
Loss at DC |
Auto Port Extension |
|
---|---|
Open, Short |
|
Apply |
|
Cancel |
|
Method |
|
Frequency 1 |
|
Frequency 2 |
|
Include Loss (ON/OFF) |
|
Adjust Mismatch (ON/OFF) |
Misc Calibration Commands |
|
---|---|
Clears the table of calibration coefficients |
|
Calibration Information |
Read/Write Measurement Data of Calibration Standards |
|
---|---|
Thru Reflection |
|
Thru Transmission |
|
Load |
|
Open |
|
Short |
Read/Write Calibration Coefficients |
||
---|---|---|
Sets method before activation |
Response Open |
|
Response Short |
||
Response Thru |
||
One-path two-port |
||
Full one-port |
||
Calibration coefficient data read/write |
||
Activates written calibration coefficients |