Please enable JavaScript to view this site.

 Network Analyzers using TRVNA software

Stimulus  |   Response  |   Scale   |   Calibration   |   Channel  |   Trace  |   Markers   |   Analysis   |   Display  |   System   |   Remote Only


Frequency Sweep | Power Sweep | Sweep Setup | IFBW | Power | Trigger: Remote Only | Segment | VVM: Data Table | Freq.Offset: Offset Adjust


note

This icon Read only indicates a read only command. This icon Write only indicates a write only command.

This icon Remote only indicates command(s) without equivalent softkeys.

Comments are in italics.


Frequency Sweep

Start

SENS:FREQ:STAR

Stop

SENS:FREQ:STOP

Center

SENS:FREQ:CENT

Span

SENS:FREQ:SPAN

 

Power Sweep

Start

SOUR:POW:STAR

Stop

SOUR:POW:STOP

Center

SOUR:POW:CENT

Span

SOUR:POW:SPAN

 

Sweep Setup

Points

SENS:SWE:POIN

Sweep Type

SENS:SWE:TYPE

Meas Delay

SENS:SWE:POIN:TIME

 

IF Bandwidth

IF Bandwidth

SENS:BAND

SENS:BWID

 

Power

Output Power

SOUR:POW

Power Slope

SOUR:POW:SLOP

CW Freq

SENS:FREQ

RF Out

OUTP

 

Trigger

Hold

INIT:CONT

Single Write only

INIT

Continuous

INIT:CONT

Trigger Source

TRIG:SOUR

Restart Remote only Write only

ABOR

 

Trigger Remote only

Generates the trigger signal Write only

TRIG

*TRG

Generates the trigger signal; the command is pending until the sweep end Write only

TRIG:SING

Waits for completion of all pending commands Write only

*WAI

Sets the OPC bit of standard event status register upon completion of all pending commands Write only

*OPC

Reads "1" upon completion of all pending commands Read only

*OPC?

Current state of the trigger system Read only

TRIG:STAT?

Waits for the specified trigger state to be reached Read only

TRIG:WAIT

 

Segment Table

Save Read only

MMEM:STOR:SEGM

Recall Read only

MMEM:LOAD:SEGM

Segment Table

SENS:SEGM:DATA

 

Vector Voltmeter

Measurement

SENS:VVM:TYPE

Format

SENS:VVM:FORM

Frequency

SENS:VVM:FREQ

Save Reference Write only

SENS:VVM:REF:MEM

Clear Reference Write only

SENS:VVM:REF:CLE

Properties > Response Digits

VVM:RES

Properties > Font Size

VVM:FONT

Measurement result data Remote only Read only

SENS:VVM:DATA?

Reference values data Remote only Read only

SENS:VVM:REF:DATA?

Data table Remote only Read only

SENS:VVM:TABL:DATA?

 

Data Table (Vector Voltmeter)

Add Data Write only

SENS:VVM:TABL:MEM

Insert Data Write only

SENS:VVM:TABL:INS

Remove Data Write only

SENS:VVM:TABL:REM

Clear Table Write only

SENS:VVM:TABL:CLE

Save Table to CSV Write only

SENS:VVM:TABL:SAVE

Frequency Offset

Freq. Offset (ON/OFF)

SENS:OFFS

Port #

Multiplier

SENS:OFFS:PORT:MULT

Divider

SENS:OFFS:PORT:DIV

Offset

SENS:OFFS:PORT:OFFS

Start

SENS:OFFS:PORT:STAR

Stop

SENS:OFFS:PORT:STOP

Port offset frequency array Remote only

SENS:OFFS:PORT:DATA?

 

Offset Adjust (Frequency Offset)

Offset Adjust (ON/OFF)

SENS:OFFS:ADJ

Select Port

SENS:OFFS:ADJ:PORT

Adjust Value

SENS:OFFS:ADJ:VAL

Contin. Adjust (ON/OFF)

SENS:OFFS:ADJ:CONT

Adjust Period

SENS:OFFS:ADJ:CONT:PER

Adjust Immediate

SENS:OFFS:ADJ:EXEC

 

 

Rev.:  24.1