Please enable JavaScript to view this site.

 Network Analyzers using TRVNA software

SCPI Command

SENSe<Ch>:CORRection:COLLect:CKIT:STAN<Std>:MEDIa {COAX|WAVE}

SENSe<Ch>:CORRection:COLLect:CKIT:STAN<Std>:MEDIa?

Description

Sets or reads out media type of the calibration standard.

command/query

Target

Standard <Std> of the calibration kit specified for channel <Ch>,

<Ch>={[1]|2|…|9}

<Std>={[1]|2|...K}, where K is the number of the standards in the calibration kit

Parameter

COAX

Coaxial

WAVE

Waveguide

Out of Range

An error occurs if the specified media type is not COAX or WAVE.

Query Response

{COAX|WAVE}

Preset Value

COAX

Equivalent Softkeys

None


Equivalent COM Command

None


 

Back to SENSe

Back to Command Finder

Back to Command Finder (From User Interface)

 

Rev.:  24.1