Please enable JavaScript to view this site.

 Network Analyzers using PXI software

Command

Description

SENS:AVER

Averaging

Averaging ON/OFF

SENS:AVER:CLE

Restart averaging

SENS:AVER:COUN

Averaging factor

SENS:BAND

IFBW

IF bandwidth

SENS:BWID

IF bandwidth

SENS:CORR:CLE

Misc Calibration Commands

Clears the table of calibration factors

SENS:CORR:COLL:CLE

Clears data of calibration standards

SENS:CORR:INF?

Information string of calibration

SENS:CORR:STAT

S-parameter error correction state

SENS:CORR:TRIG:FREE

Calibration trigger source

SENS:CORR:TYPE?

Information about trace (calibration type, number of ports)

SENS:CORR:COEF

Read/Write Calibration Coefficients

Calibration coefficient data

SENS:CORR:COEF:METH:ERES

Selects one-path two-port method

SENS:CORR:COEF:METH:OPEN

Selects Response Open method

SENS:CORR:COEF:METH:SHOR

Selects Response Short method

SENS:CORR:COEF:METH:SOLT1

Selects full one-port method

SENS:CORR:COEF:METH:SOLT2

Selects full two-port method

SENS:CORR:COEF:METH:THRU

Selects Response Thru method

SENS:CORR:COEF:SAVE

Enables calibration coefficients

SENS:CORR:COLL:ADAP:DEL

Adapter Removal/ Insertion

Approximate delay of the adapter

SENS:CORR:COLL:ADAP:LENG

Approximate length of the adapter

SENS:CORR:COLL:ADAP:UNIT

Delay units

SENS:CORR:COLL:ADAP:MED

Adapter media

SENS:CORR:COLL:ADAP:PERM

Permittivity of the adapter media

SENS:CORR:COLL:ADAP:WAV:CUT

Cutoff frequency of the waveguide adapter

SENS:CORR:COLL:METH:ADAP:REM

Adapter Removal/Insertion ON/OFF

SENS:CORR:COLL:CKIT

Calibration Kit Management

Calibration kit selection

SENS:CORR:COLL:CKIT:DESC

Calibration kit description string

SENS:CORR:COLL:CKIT:LAB

Calibration kit label

SENS:CORR:COLL:CKIT:RES

Remove or restore a calibration kit

SENS:CORR:COLL:CKIT:STAN:INS

Insert the standard into a calibration kit

SENS:CORR:COLL:CKIT:STAN:REM

Delete the standard from a calibration kit

SENS:CORR:COLL:CKIT:ORD:LOAD

Assigning Class to Calibration Standard

"Load" class

SENS:CORR:COLL:CKIT:ORD:OPEN

"Open" class

SENS:CORR:COLL:CKIT:ORD:SEL

Assignment of subclass

SENS:CORR:COLL:CKIT:ORD:SHOR

"Short" class

SENS:CORR:COLL:CKIT:ORD:THRU

"Thru" class

SENS:CORR:COLL:CKIT:ORD:TRLL

"TRL Line" class

SENS:CORR:COLL:CKIT:ORD:TRLT

"TRL Thru" class

SENS:CORR:COLL:CKIT:ORD:TRLR

"TRL Reflect" class

SENS:CORR:COLL:CKIT:STAN:ARB

Calibration Standard Definition

Arbitrary impedance (Load)

SENS:CORR:COLL:CKIT:STAN:C0

Capacitance C0 (Open)

SENS:CORR:COLL:CKIT:STAN:C1

Capacitance C1 (Open)

SENS:CORR:COLL:CKIT:STAN:C2

Capacitance C2 (Open)

SENS:CORR:COLL:CKIT:STAN:C3

Capacitance C3 (Open)

SENS:CORR:COLL:CKIT:STAN:COUN?

Number of standards in the calibration kit

SENS:CORR:COLL:CKIT:STAN:DATA

S-parameters of the data-based calibration standard

SENS:CORR:COLL:CKIT:STAN:DEL

Offset delay

SENS:CORR:COLL:CKIT:STAN:FMAX

Max frequency

SENS:CORR:COLL:CKIT:STAN:FMIN

Min frequency

SENS:CORR:COLL:CKIT:STAN:L0

Inductance L0 (Short)

SENS:CORR:COLL:CKIT:STAN:L1

Inductance L1 (Short)

SENS:CORR:COLL:CKIT:STAN:L2

Inductance L2 (Short)

SENS:CORR:COLL:CKIT:STAN:L3

Inductance L3 (Short)

SENS:CORR:COLL:CKIT:STAN:LAB

Standard label

SENS:CORR:COLL:CKIT:STAN:LOSS

Offset loss

SENS:CORR:COLL:CKIT:STAN:TYPE

Standard type

SENS:CORR:COLL:CKIT:STAN:Z0

Offset Z0

SENS:CORR:COLL:DATA:ISOL

Read/Write Measurement of Calibration Standards

Measurement array of Isolation

SENS:CORR:COLL:DATA:LOAD

Measurement array of Load

SENS:CORR:COLL:DATA:OPEN

Measurement array of Open

SENS:CORR:COLL:DATA:SHOR

Measurement array of Short

SENS:CORR:COLL:DATA:THRU:MATC

Reflection measurement array of Thru

SENS:CORR:COLL:DATA:THRU:TRAN

Transmission measurement array of Thru

SENS:CORR:COLL:ECAL:CCH

Automatic Calibration Module

Confidence check of calibration coefficients

SENS:CORR:COLL:ECAL:ERES

Procedure of one path two-port calibration

SENS:CORR:COLL:ECAL:INF?

Information about connected module

SENS:CORR:COLL:ECAL:ORI:EXEC

Auto-Orientation procedure

SENS:CORR:COLL:ECAL:ORI:STAT

Auto-Orientation ON/OFF

SENS:CORR:COLL:ECAL:PATH

Manual module orientation

SENS:CORR:COLL:ECAL:SOLT1

Procedure of one-port calibration

SENS:CORR:COLL:ECAL:SOLT2

Procedure of full two-port calibration

SENS:CORR:COLL:ECAL:THER:COMP

Thermo compensation ON/OFF

SENS:CORR:COLL:ECAL:UCH

Characterization number

SENS:CORR:COLL:ECAL:UTHR:STAT

Unknown Thru feature ON/OFF

SENS:CORR:COLL:ISOL

Measurement of Calibration Standards

Isolation

SENS:CORR:COLL:LOAD

Load

SENS:CORR:COLL:OPEN

Open

SENS:CORR:COLL:SHOR

Short

SENS:CORR:COLL:THRU

Thru

SENS:CORR:COLL:TRLL

TRL Line

SENS:CORR:COLL:TRLT

TRL Thru

SENS:CORR:COLL:TRLR

TRL Reflect

SENS:CORR:COLL:SUBC

Subclass number

SENS:CORR:COLL:METH:ERES

Calibration Method

One path two-port

SENS:CORR:COLL:METH:OPEN

Response Open

SENS:CORR:COLL:METH:SHOR

Response Short

SENS:CORR:COLL:METH:SOLT1

Full one-port (SOL)

SENS:CORR:COLL:METH:SOLT2

Full two-port (SOLT)

SENS:CORR:COLL:METH:THRU

Response Thru

SENS:CORR:COLL:METH:TRL:MULT

Multi-line TRL option ON/OFF

SENS:CORR:COLL:METH:TRL2

Two-port TRL

SENS:CORR:COLL:METH:TYPE?

Calibration method query.

SENS:CORR:COLL:SAVE

Calibration Completion

Calibration completion

SENS:CORR:COLL:THRU:ADD:DEL

Unknown Thru Addition

Approximate delay of the Thru

SENS:CORR:COLL:THRU:ADD:LENG

Approximate length of the Thru

SENS:CORR:COLL:THRU:ADD:UNIT

Delay Units

SENS:CORR:COLL:THRU:ADD:MED

Thru Media

SENS:CORR:COLL:THRU:ADD:PERM

Permittivity of the Thru media

SENS:CORR:COLL:THRU:ADD:WAV:CUT

Cutoff frequency of the waveguide Thru

SENS:CORR:COLL:THRU:ADD:FULL2:COMP

Completion of the full two-port calibration

SENS:CORR:EXT

Port Extension

Port extension ON/OFF

SENS:CORR:EXT:PORT:FREQ

Values of "Frequency1" and "Frequency2"

SENS:CORR:EXT:PORT:INCL

Loss compensation ON/OFF

SENS:CORR:EXT:PORT:LDC

Value "Loss at DC"

SENS:CORR:EXT:PORT:LOSS

Values of "Loss 1" and "Loss 2"

SENS:CORR:EXT:PORT:TIME

Extension Port n

SENS:CORR:EXT:AUTO:CONF

Auto Port Extension

Frequency range configuration

SENS:CORR:EXT:AUTO:DCOF

"Loss at DC" value ON/OFF

SENS:CORR:EXT:AUTO:LOSS

"Loss1" and "Loss2" values ON/OFF

SENS:CORR:EXT:AUTO:MEAS

Measurement of Short or Open

SENS:CORR:EXT:AUTO:PORT

Auto port extension for the specified port ON/OFF

SENS:CORR:EXT:AUTO:RES

Restart averaging between Short and Open

SENS:CORR:EXT:AUTO:STAR

Start frequency of user span

SENS:CORR:EXT:AUTO:STOP

Stop frequency of user span

SENS:CORR:IMP

System Impedance Setting

System Z0

SENS:CORR:IMP:SEL:AUTO

Auto-select Z0 ON/OFF

SENS:CORR:PORT:IMP

System Z0 for the specified port

SENS:CORR:OFFS:CLE

Scalar Mixer Calibration

Clears calibration coefficient table

SENS:CORR:OFFS:COLL:CLE

Clears calibration data

SENS:CORR:OFFS:COLL:DIR

Calibration direction

SENS:CORR:OFFS:COLL:ECAL

Measure all standards using ACM

SENS:CORR:OFFS:COLL:LOAD

Measure the Load standard

SENS:CORR:OFFS:COLL:METH:SMIX2

Calibration port

SENS:CORR:OFFS:COLL:OPEN

Measure the Open standard

SENS:CORR:OFFS:COLL:PMET

Measure power

SENS:CORR:OFFS:COLL:SHOR

Measure the Short standard

SENS:CORR:OFFS:COLL:THRU

Measure the Thru standard

SENS:CORR:OFFS:COLL:SAVE

Completes calibration

SENS:CORR:REC

Receiver Calibration

Receiver correction ON/OFF

SENS:CORR:REC:COLL:ACQ

Calibration procedure for both receivers

SENS:CORR:REC:COLL:RCH:ACQ

Reference receiver calibration procedure

SENS:CORR:REC:COLL:TCH:ACQ

Test receiver calibration procedure

SENS:CORR:REC:OFFS:AMPL

Power offset

SENS:CORR:TRAN:TIME:FREQ

Cable Correction

Frequency at which cable loss specified

SENS:CORR:TRAN:TIME:LOSS

Cable loss

SENS:CORR:TRAN:TIME:RVEL

Cable velocity factor

SENS:CORR:TRAN:TIME:STAT

Cable correction ON/OFF

SENS:CORR:VMC:COLL:ECAL:SAVE

Vector Mixer Calibration

Complete the calibration using ACM

SENS:CORR:VMC:COLL:PORT

Port number for calibration mixer with LPF filter

SENS:CORR:VMC:COLL:IF:SEL

IF frequency (RF+LO, RF-LO, LO-RF)

SENS:CORR:VMC:COLL:LO:FREQ

LO frequency

SENS:CORR:VMC:COLL:LOAD

Measure the Load standard

SENS:CORR:VMC:COLL:OPEN

Measure the Open standard

SENS:CORR:VMC:COLL:SHOR

Measure the Short standard

SENS:CORR:VMC:COLL:OPT

Setup option (de-embedding calibration mixer + filter at completion of calibration) ON/OFF

SENS:CORR:VMC:COLL:SAVE

Complete the calibration, calculate S-parameters, write the touchstone file

SENS:DATA:CORR?

Data Transfer

Corrected S-parameter data or corrected receiver data

SENS:DATA:RAWD?

Raw S-parameter data or raw receiver data

SENS:FREQ:DATA?

Stimulus data

SENS:FREQ

Stimulus Settings

Fixed frequency for a power sweep

SENS:FREQ:CENT

Center frequency

SENS:FREQ:SPAN

Span frequency

SENS:FREQ:STAR

Start frequency

SENS:FREQ:STOP

Stop frequency

SENS:SEGM:DATA

Segment sweep table

SENS:SWE:CW:TIME

Sweep Time

SENS:SWE:POIN

Number of points

SENS:SWE:POIN:TIME

Point delay

SENS:SWE:REV

Reverse sweep ON/OFF

SENS:SWE:TYPE

Sweep type

SENS:OFFS:ADJ

Mixer Measurements

Frequency offset adjust ON/OFF

SENS:OFFS:ADJ:CONT:PER

Adjust period

SENS:OFFS:ADJ:EXEC

Executes adjustment once

SENS:OFFS:ADJ:PATH

Adjustment path

SENS:OFFS:ADJ:PORT

Adjusted Port

SENS:OFFS:ADJ:VAL

Adjust Value

SENS:OFFS

Frequency offset ON/OFF

SENS:OFFS:PORT:DATA?

Port offset data

SENS:OFFS:PORT:DIV

Port offset settings

Divisor

SENS:OFFS:PORT:MULT

Multiplier

SENS:OFFS:PORT:OFFS

Offset

SENS:OFFS:PORT:STAR

Start

SENS:OFFS:PORT:STOP

Stop

SENS:OFFS:REC:DATA?

Receiver offset data

SENS:OFFS:REC:DIV

Receiver offset settings

Divisor

SENS:OFFS:REC:MULT

Multiplier

SENS:OFFS:REC:OFFS

Offset

SENS:OFFS:REC:STAR

Start

SENS:OFFS:REC:STOP

Stop

SENS:OFFS:SOUR:DATA?

Source offset data

SENS:OFFS:SOUR:DIV

Source offset settings

Divisor

SENS:OFFS:SOUR:MULT

Multiplier

SENS:OFFS:SOUR:OFFS

Offset

SENS:OFFS:SOUR:STAR

Start

SENS:OFFS:SOUR:STOP

Stop

SENS:OFFS:TYPE

Offset type

SENS:ROSC:SOUR

Analyzer Parameters

Reference source

SENS:ROSC:EXT:ROUT

Route of the external reference frequency

Rev.:  22.3