Command |
Description |
COM analog |
|
---|---|---|---|
Conversion ON/OFF |
+ |
||
Conversion type |
+ |
||
Equivalent distance |
- |
||
Distance units |
- |
||
Media |
- |
||
Velocity factor |
- |
||
Electrical delay |
+ |
||
Waveguide cutoff frequency |
- |
||
Value of the phase offset |
+ |
||
Interpolation/extrapolation status of the error correction |
+ |
||
Formatted data array |
+ |
||
Formatted memory array |
+ |
||
Corrected data array |
+ |
||
Corrected memory array |
+ |
||
X-axis values array |
+ |
||
Gate type |
+ |
||
Gate center |
+ |
||
Gate shape |
+ |
||
Gate span |
+ |
||
Gate start |
+ |
||
Gating function ON/OFF |
+ |
||
Gate stop |
+ |
||
Trace format |
+ |
||
Number of traces in the channel |
+ |
||
Active trace number (write) |
+ |
||
Common Z value |
+ |
||
Common Z conversion ON/OFF |
+ |
||
Differential Z value |
+ |
||
Differential Z conversion ON/OFF |
+ |
||
Capacitance of C element |
+ |
||
Conductance of G element |
+ |
||
Inductance of L element |
+ |
||
Resistance of R element |
+ |
||
Type of the differential matching circuit |
+ |
||
Name of *.S2P touchstone file |
+ |
||
Differential matching ON/OFF |
+ |
||
Type of balanced device |
+ |
||
Parameter for "BALanced" device |
+ |
||
Parameter for "BBALanced" device |
+ |
||
Parameter for "SBALanced" device |
+ |
||
Parameter for "SSBalanced" device |
+ |
||
Balance-Unbalance ON/OFF |
+ |
||
Assigned ports for "BALanced" type |
+ |
||
Assigned ports for "BBALanced" type |
+ |
||
Assigned ports for "SBALanced" type |
+ |
||
Assigned ports for "SSBalanced" type |
+ |
||
Balance-Unbalance property indication ON/OFF |
+ |
||
Name of *.S4P Touchstone file |
+ |
||
Processing type |
+ |
||
Embedding/De-embedding ON/OFF |
+ |
||
Test port assignment (Topology=A) |
+ |
||
Test port assignment (Topology=B) |
+ |
||
Test port assignment (Topology=C) |
+ |
||
Topology (A|B|C) |
+ |
||
De-embedding ON/OFF |
+ |
||
De-embedding for specified port ON/OFF |
+ |
||
Name of *.S2P touchstone file of the de-embedded circuit |
+ |
||
Embedding ON/OFF |
+ |
||
Embedding for specified port ON/OFF |
+ |
||
Name of *.S2P Touchstone file of the embedded circuit |
+ |
||
Z0 Real part, Imaginary part is "0" |
+ |
||
Z0 Real part |
- |
||
Z0 Imaginary part |
- |
||
Port Z conversion ON/OFF |
+ |
||
Theory of Port Z Conversion |
- |
||
Fixture simulation ON/OFF |
+ |
||
Analysis result data array |
+ |
||
Arbitrary sweep range ON/OFF |
+ |
||
Coupling range ON/OFF |
+ |
||
Analysis range start |
+ |
||
Analysis range stop |
+ |
||
Execute analysis |
+ |
||
Lower limit for the peak excursion value |
+ |
||
Number of points (data pairs) |
+ |
||
Peak polarity |
+ |
||
Target level |
+ |
||
Transition type |
+ |
||
Analysis type |
+ |
||
Trace hold type |
- |
||
Trace hold restart |
- |
||
Limit test ON/OFF |
+ |
||
Limit line table |
+ |
||
Limits display ON/OFF |
+ |
||
Limit test result |
+ |
||
Limit line Y-offset |
+ |
||
Limit line Y-offset to active marker value |
+ |
||
Limit line X-offset |
+ |
||
Limit test result report |
+ |
||
Failed points |
+ |
||
Stimulus values of failed points |
+ |
||
Marker ON/OFF |
+ |
||
Sets active marker |
+ |
||
Number of markers |
+ |
||
Coupling of markers ON/OFF |
+ |
||
Response and stimulus values of all trace marker |
+ |
||
Marker discrete mode ON/OFF |
+ |
||
Reference marker ON/OFF |
+ |
||
Stimulus value of marker |
+ |
||
Response value of marker |
+ |
||
Bandwidth search ON/OFF |
+ |
||
Bandwidth search result |
+ |
||
Reference of search |
+ |
||
Bandwidth threshold value |
+ |
||
Type of search |
+ |
||
Arbitrary search range ON/OFF |
+ |
||
Coupling of marker search ranges ON/OFF |
+ |
||
Start of the marker search range |
+ |
||
Stop of the marker search range |
+ |
||
Executes search |
+ |
||
Peak excursion value |
+ |
||
Peak polarity |
+ |
||
Target value |
+ |
||
Marker search tracking ON/OFF |
+ |
||
Type of target transition |
+ |
||
Search type |
+ |
||
Flatness function data |
+ |
||
Marker flatness ON/OFF |
+ |
||
Marker specifying start of frequency range |
+ |
||
Marker specifying stop of frequency range |
+ |
||
Sets item value according to the position of the marker |
+ |
||
Math operation |
+ |
||
Data => Memory |
+ |
||
Math statistics ON/OFF |
+ |
||
Math statistics data |
+ |
||
Partial frequency range ON/OFF |
+ |
||
Marker specifying start of frequency range |
+ |
||
Marker specifying stop of frequency range |
+ |
||
Measurement parameter of a trace |
+ |
||
Number of the stimulus port for an absolute measurements or DC Voltage measurements |
+ |
||
Ripple limit test ON/OFF |
+ |
||
Ripple limit line table |
+ |
||
Ripple Limit line display ON/OFF |
+ |
||
Number of band for ripple value display |
+ |
||
Display type of ripple value |
+ |
||
Ripple limit test result |
+ |
||
Ripple limit test result report |
+ |
||
Trace smoothing ON/OFF |
+ |
||
Smoothing aperture |
+ |
||
Selects Band-pass/Low-pass type |
+ |
||
Time domain center |
+ |
||
DC value |
- |
||
DC extrapolation ON/OFF |
- |
||
Impulse Width |
+ |
||
Kaiser-Bessel β |
+ |
||
Sets requency Low-Pass |
+ |
||
Selects One way/Round trip |
+ |
||
Time domain Span |
+ |
||
Time domain Start |
+ |
||
Time domain Stop |
+ |
||
Time domain transformation ON/OFF |
+ |
||
Step rise time |
+ |
||
Selects Impulse/Step type |
+ |
||
Time domain Unit |
+ |