Please enable JavaScript to view this site.

 Network Analyzers using S2VNA software

SCPI Command

SENSe<ch>:PLS2:ADVanced:LINK:NMOD {PGEN1...PGEN7|EXT1...EXT6|LOW|HIGH|SYNC2}

SENSe<ch>:PLS2:ADVanced:LINK:NMOD?

Description

Sets the signal source at the input of the standard modulator. The signal source is determined by the command parameter. A high signal level opens the pulse modulator.

Note: The command is used in advanced mode, it is not used in basic pulse modes. Application requires knowledge of the internal structure of the analyzer.

Note: S5243 model only.

command/query

Target

Channel <Ch> = {[1]|2| ... 16}

Parameter

<char> signal source at the input of the standard modulator:

PGEN1...PGEN7

Generator PG1...PG7

EXT1...EXT6

"Ext Trig Out", "Ext Trig In", "Pulse Trig (3...6)" signal

SYNC2

Internal line SYNC2 signal

LOW

Constant low level

HIGH

Constant high level

Query Response

{PGEN1...PGEN7|EXT1...EXT6|LOW|HIGH|SYNC2}

Related Commands

SENS:PLS2:ADV:APPL

Equivalent Softkeys

Stimulus > Pulse Meas > Advanced Settings... > Std Modulator -> {source}


Equivalent COM Command

None


 

Back to Pulse Measurement S5243

Back to Command Finder (From User Interface)

 

Rev.:  24.1