Command |
Description |
COM analog |
|
---|---|---|---|
S-parameter Conversion |
Conversion ON/OFF |
+ |
|
Conversion type |
+ |
||
Electrical Delay |
Equivalent distance |
- |
|
Distance units |
- |
||
Media |
- |
||
Velocity factor |
- |
||
Electrical delay |
+ |
||
Waveguide cutoff frequency |
- |
||
Phase Offset |
Value of the phase offset |
+ |
|
Interpolation/extrapolation status of the error correction |
+ |
||
Formatted data array |
+ |
||
Formatted memory array |
+ |
||
Corrected data array |
+ |
||
Corrected memory array |
+ |
||
X-axis values array |
+ |
||
Gating |
Gate type |
+ |
|
Gate center |
+ |
||
Gate shape |
+ |
||
Gate span |
+ |
||
Gate start |
+ |
||
Gating function ON/OFF |
+ |
||
Gate stop |
+ |
||
Trace format |
+ |
||
Number of traces in the channel |
+ |
||
Active trace number (write) |
+ |
||
Two-port Network De-embedding |
De-embedding ON/OFF |
+ |
|
De-embedding for specified port ON/OFF |
+ |
||
Name of *.S2P touchstone file of the de-embedded circuit |
+ |
||
Two-port Network Embedding |
Embedding ON/OFF |
+ |
|
Embedding for specified port ON/OFF |
+ |
||
Name of *.S2P Touchstone file of the embedded circuit |
+ |
||
Port Impedance Conversion |
Z0 Real part, Imaginary part is "0" |
+ |
|
Z0 Real part |
- |
||
Z0 Imaginary part |
- |
||
Port Z conversion ON/OFF |
+ |
||
Theory of Port Z Conversion |
- |
||
Fixture Simulation Function |
Fixture simulation ON/OFF |
+ |
|
Trace Analysis |
Analysis result data array |
+ |
|
Arbitrary sweep range ON/OFF |
+ |
||
Coupling range ON/OFF |
+ |
||
Analysis range start |
+ |
||
Analysis range stop |
+ |
||
Execute analysis |
+ |
||
Lower limit for the peak excursion value |
+ |
||
Number of points (data pairs) |
+ |
||
Peak polarity |
+ |
||
Target level |
+ |
||
Transition type |
+ |
||
Analysis type |
+ |
||
Trace Hold |
Trace hold type |
- |
|
Trace hold restart |
- |
||
Limit test ON/OFF |
+ |
||
Limit line table |
+ |
||
Limits display ON/OFF |
+ |
||
Limit test result |
+ |
||
Limit line Y-offset |
+ |
||
Limit line Y-offset to active marker value |
+ |
||
Limit line X-offset |
+ |
||
Limit test result report |
+ |
||
Failed points |
+ |
||
Stimulus values of failed points |
+ |
||
Marker ON/OFF |
+ |
||
Sets active marker |
+ |
||
Number of markers |
+ |
||
Coupling of markers ON/OFF |
+ |
||
Response and stimulus values of all marker |
+ |
||
Marker discrete mode ON/OFF |
+ |
||
Reference marker ON/OFF |
+ |
||
Stimulus value of marker |
+ |
||
Response value of marker |
+ |
||
Bandwidth Search |
Bandwidth search ON/OFF |
+ |
|
Bandwidth search result |
+ |
||
Reference of search |
+ |
||
Bandwidth threshold value |
+ |
||
Type of search |
+ |
||
Marker Search |
Arbitrary search range ON/OFF |
+ |
|
Coupling of marker search ranges ON/OFF |
+ |
||
Start of the marker search range |
+ |
||
Stop of the marker search range |
+ |
||
Executes search |
+ |
||
Peak excursion value |
+ |
||
Peak polarity |
+ |
||
Target value |
+ |
||
Marker search tracking ON/OFF |
+ |
||
Type of target transition |
+ |
||
Search type |
+ |
||
Flatness |
Flatness function data |
+ |
|
Marker flatness ON/OFF |
+ |
||
Marker specifying start of frequency range |
+ |
||
Marker specifying stop of frequency range |
+ |
||
Marker Functions |
Sets item value according to the position of the marker |
+ |
|
Math operation |
+ |
||
Data => Memory |
+ |
||
Statistic |
Math statistics ON/OFF |
+ |
|
Math statistics data |
+ |
||
Partial frequency range ON/OFF |
+ |
||
Marker specifying start of frequency range |
+ |
||
Marker specifying stop of frequency range |
+ |
||
Measurement Setting |
Measurement parameter of a trace |
+ |
|
Number of the stimulus port for an absolute measurements or DC Voltage measurements |
+ |
||
Ripple limit test ON/OFF |
+ |
||
Ripple limit line table |
+ |
||
Ripple Limit line display ON/OFF |
+ |
||
Number of band for ripple value display |
+ |
||
Display type of ripple value |
+ |
||
Ripple limit test result |
+ |
||
Ripple limit test result report |
+ |
||
Smoothing |
Trace smoothing ON/OFF |
+ |
|
Smoothing aperture |
+ |
||
Setting Time Domain Parameters |
Selects Band-pass/Low-pass type |
+ |
|
Time domain center |
+ |
||
DC value |
- |
||
DC extrapolation ON/OFF |
- |
||
Impulse Width |
+ |
||
Kaiser-Bessel β |
+ |
||
Sets requency Low-Pass |
+ |
||
Selects One way/Round trip |
+ |
||
Time domain Span |
+ |
||
Time domain Start |
+ |
||
Time domain Stop |
+ |
||
Time domain transformation ON/OFF |
+ |
||
Step rise time |
+ |
||
Selects Impulse/Step type |
+ |
||
Time domain Unit |
+ |