Please enable JavaScript to view this site.

 Network Analyzers using S4VNA software

Command

Description

COM analog

SYST:BEEP:COMP:IMM

Analyzer Parameters

Generates completion beep

+

SYST:BEEP:COMP:STAT

Completion beeper ON/OFF

+

SYST:BEEP:WARN:IMM

Generates warning beep

+

SYST:BEEP:WARN:STAT

Warning beeper ON/OFF

+

SYST:CAP:CURR:CONS?

Capability to measure current consumption

-

SYST:CURR:CONS?

Measured current consumption

-

SYST:CORR

System correction ON/OFF

+

SYST:CYCL:TIME:MEAS?

Measured cycle

+

SYST:CYCL:TIME:METH

Cycle time measurement method

-

SYST:CYCL:TIME:REST

Restart cycle time measurement

-

SYST:DATE

Current date

+

SYST:DYN:RANG:EXT

Dynamic range extension ON/OFF

-

SYST:READ?

Analyzer readiness status

+

SYST:REC:OVER:POW

Power trip ON/OFF

-

SYST:TEMP:SENS?

Reads the Analyzer temperature

+

SYST:TERM

Analyzer software shutdown

+

SYST:TIME

Current time

+

SYST:CAP:IFBW:MAX?

Analyzer Capabilities

Upper limit of IFBW

-

SYST:CAP:IFBW:MIN?

Lower limit of IFBW

-

SYST:CONN:SER:NUMB

Analyzer Serial N

-

SYST:SERV:PVER:INT

Performance verification period

-

SYST:SERV:PVER:LAST

Performance verification last date

-

SYST:SERV:PVER:NEXT

Performance verification next date

-

SYST:COMM:ECAL:CHEC

Automatic Calibration Module

"CHECK" module state

+

SYST:COMM:ECAL:DATA?

Characterization data of AutoCal module

-

SYST:COMM:ECAL:FREQ:DATA?

Characterization frequency array of AutoCal module

-

SYST:COMM:ECAL:POIN?

Number of characterization points of AutoCal module

-

SYST:COMM:ECAL:IMP

Impedance state of module port

+

SYST:COMM:ECAL:READ?

Module readiness status

-

SYST:COMM:ECAL:TEMP:SENS?

Module temperature

+

SYST:COMM:ECAL:THRU

"THRU" module state

+

SYST:COMM:PSEN:NI568x:RES:NAME

Power Sensor Settings

NI568x power sensor resource name

-

SYST:COMM:PSEN:READ?

Power sensor readiness

-

SYST:COMM:PSEN:TYPE

Power sensor type

-

SYST:COMM:PSEN:ZERO

Power Calibration

Zeroes the power sensor

-

SYST:ERR?

Status System

Reads the error message queue

-

SYST:TEST?

Textual description of Analyzer self-test

-

SYST:FREQ:EXT:RFP:POW

Frequency Extension System

RF Port Power

-

SYST:FREQ:EXT:RFP:PSL

RF Port Power Slope

-

SYST:FREQ:EXT:LOP:POW

LO Port Power

-

SYST:FREQ:EXT:LOP:PSL

LO Port Power Slope

-

SYST:FREQ:EXT:TYPE

Frequency extender type

-

SYST:FREQ:EXT:PORT:CONN?

Extender connection status

-

SYST:FREQ:EXT:PORT:SER?

Extender serial number

-

SYST:FREQ:EXT:PORT:TEMP:SENS?

Frequency extender temperature

-

SYST:HIDE

Interface Settings

Minimizes the Analyzer window

+

SYST:LOC

Sets the local mode

+

SYST:REM

Sets the remote mode

+

SYST:RWL

Sets the remote mode with lock

+

SYST:SHOW

Restores the Analyzer window

+

SYST:PRES

Presets

Reset to default settings

+

SYST:REC:DIR:ACC

Direct Receiver Access

Direct access ON/OFF

-

Rev.:  22.4