Default values defined in the process of the initial factory setup.
Parameter Description |
Default Setting |
Parameter Setting Object |
---|---|---|
Data Saving Type |
State and Calibration |
Analyzer |
Touchstone Data Format |
Real-Imaginary |
Analyzer |
Allocation of Channels |
Analyzer |
|
Active Channel Number |
1 |
Analyzer |
Marker Value Identification Capacity (Stimulus) |
8 digits |
Analyzer |
Marker Value Identification Capacity (Response) |
5 digits |
Analyzer |
Reference Frequency Source |
Internal |
Analyzer |
Trigger Signal Source |
Internal |
Analyzer |
System Correction |
ON |
Analyzer |
Allocation of Traces |
Channel |
|
Vertical Divisions |
10 |
Channel |
Channel Title Bar |
OFF |
Channel |
Channel Title |
Empty |
Channel |
«FAIL» Label Display (Limit Test) |
OFF |
Channel |
Segment Sweep Frequency Axis Display |
Frequency Order |
Channel |
Traces per Channel |
1 |
Channel |
Active Trace Number |
1 |
Channel |
Marker Coupling |
OFF |
Channel |
Sweep Type |
Linear Frequency |
Channel |
Number of Points |
201 |
Channel |
Stimulus Start Frequency |
Instrument Min. |
Channel |
Stimulus Stop Frequency |
Instrument Max. |
Channel |
Stimulus CW Frequency |
Middle of Freq Range of Instrument |
Channel |
Stimulus Start Power Level |
Instrument Min. |
Channel |
Stimulus Stop Power Level |
Instrument Max. |
Channel |
Stimulus Power Level |
0 dBm |
Channel |
Stimulus Power Slope |
0 dBm |
Channel |
Stimulus IF Bandwidth |
10 kHz |
Channel |
Sweep Measurement Delay |
0 sec. |
Channel |
Sweep Range Setting |
Start / Stop |
Channel |
Number of Segments |
1 |
Channel |
Points per Segment |
2 |
Channel |
Segment Start Frequency |
Instrument Min. |
Channel |
Segment Stop Frequency |
Instrument Min. |
Channel |
Segment Sweep Power Level |
0 dBm |
Channel |
Segment Sweep IF Bandwidth |
10 kHz |
Channel |
Segment Sweep Measurement Delay |
0 sec. |
Channel |
Segment Sweep Power Level (Table Display) |
OFF |
Channel |
Segment Sweep IF Bandwidth (Table Display) |
OFF |
Channel |
Segment Sweep Measurement Delay (Table Display) |
OFF |
Channel |
Segment Sweep Range Setting |
Start / Stop |
Channel |
Averaging |
OFF |
Channel |
Averaging Factor |
10 |
Channel |
Trigger Mode |
Continuous |
Channel |
Table of Calibration Coefficients |
Empty |
Channel |
Error Correction |
OFF |
Channel |
Port Z Conversion |
OFF |
Channel |
Port 1 Simulated Impedance |
Instrument Nominal |
Channel |
Port 2 Simulated Impedance |
Instrument Nominal |
Channel |
Port 1 De-embedding |
OFF |
Channel |
Port 2 De-embedding |
OFF |
Channel |
Port 1 De-embedding S-parameter File |
Empty |
Channel |
Port 2 De-embedding S-parameter File |
Empty |
Channel |
Port 1 Embedding |
OFF |
Channel |
Port 2 Embedding |
OFF |
Channel |
Port 1 Embedding User File |
Empty |
Channel |
Port 2 Embedding User File |
Empty |
Channel |
Measurement Parameter |
S11 |
Trace |
Trace Scale |
10 dB / Div. |
Trace |
Reference Level Value |
0 dB |
Trace |
Reference Level Position |
5 Div. |
Trace |
Data Math |
OFF |
Trace |
Phase Offset |
0° |
Trace |
Electrical Delay |
0 sec. |
Trace |
S-parameter Conversion |
OFF |
Trace |
S-parameter Conversion Function |
Z: Reflection |
Trace |
Trace Display Format |
Logarithmic Magnitude (dB) |
Trace |
Time Domain Transformation |
OFF |
Trace |
Time Domain Transformation Start |
–10 nsec. |
Trace |
Time Domain Transformation Stop |
10 nsec. |
Trace |
Time Domain Kaiser-Beta |
6 |
Trace |
Time Domain Transformation Type |
Bandpass |
Trace |
Time Domain Gate |
ON |
Trace |
Time Domain Gate Start |
–10 ns |
Trace |
Time Domain Gate Stop |
10 ns |
Trace |
Time Domain Gate Type |
Bandpass |
Trace |
Time Domain Gate Shape |
Normal |
Trace |
Smoothing |
OFF |
Trace |
Smoothing Aperture |
1% |
Trace |
Trace Display Mode |
Data |
Trace |
Limit Test |
OFF |
Trace |
Limit Line Display |
OFF |
Trace |
Defined Limit Lines |
Empty |
Trace |
Number of Markers |
0 |
Trace |
Marker Position |
Middle of Freq Range of Instrument |
Trace |
Marker Search |
Maximum |
Trace |
Marker Tracking |
OFF |
Trace |
Marker Search Target |
0 dB |
Trace |
Marker Search Target Transition |
Both |
Trace |
Marker Search Peak Polarity |
Positive |
Trace |
Marker Search Peak Excursion |
1 dB |
Trace |
Bandwidth Parameter Search |
OFF |
Trace |
Marker Search Bandwidth Value |
–3 dB |
Trace |
Marker Search Range |
OFF |
Trace |
Marker Search Start |
0 |
Trace |
Marker Search Stop |
0 |
Trace |